The growing global demand for energy calls for more efficient and higher-capacity power transmission solutions. Superconducting cables offer current densities 4 to 5 times greater than conventional cables and, when combined with direct current (DC) technology, enable reduced losses and more efficient long-distance power transport. Realising their full potential, however, requires sophisticated modelling tools to study their behaviour within the power grid, both under normal operating conditions and during fault events. This PhD research addresses three interconnected modelling challenges. First, the electrothermal modelling of superconducting cables was investigated, with particular focus on the accurate calculation of inductance coefficients between cable layers, a critical parameter governing current distribution during transients. A comparative study of existing analytical methodologies revealed significant inaccuracies in approaches commonly adopted in the literature, and a more reliable formulation was identified and validated. Second, a simplified Modular Multilevel Converter (MMC) model was developed for DC fault simulations. By introducing fictitious circuit components to replicate the converter behaviour between fault occurrence and protection activation, the model achieves an effective trade-off between complexity and accuracy, providing reliable fault current estimates across a wide range of scenarios without requiring full detailed converter models. Third, a power flow methodology for superconducting multi-terminal DC grids was developed. The study showed that, unlike in conventional systems, the resistive contribution of DC circuit breakers and inductors dominates over that of the cables, requiring a revision of standard assumptions. The analysis also identified a maximum efficiency operating point for superconducting cables, linked to the constant cooling power demand, making load flow analysis an essential tool for proper infrastructure exploitation.
Abstract
The growing global demand for energy calls for more efficient and higher-capacity power transmission solutions. Superconducting cables offer current densities 4 to 5 times greater than conventional cables and, when combined with direct current (DC) technology, enable reduced losses and more efficient long-distance power transport. Realising their full potential, however, requires sophisticated modelling tools to study their behaviour within the power grid, both under normal operating conditions and during fault events. This PhD research addresses three interconnected modelling challenges. First, the electrothermal modelling of superconducting cables was investigated, with particular focus on the accurate calculation of inductance coefficients between cable layers, a critical parameter governing current distribution during transients. A comparative study of existing analytical methodologies revealed significant inaccuracies in approaches commonly adopted in the literature, and a more reliable formulation was identified and validated. Second, a simplified Modular Multilevel Converter (MMC) model was developed for DC fault simulations. By introducing fictitious circuit components to replicate the converter behaviour between fault occurrence and protection activation, the model achieves an effective trade-off between complexity and accuracy, providing reliable fault current estimates across a wide range of scenarios without requiring full detailed converter models. Third, a power flow methodology for superconducting multi-terminal DC grids was developed. The study showed that, unlike in conventional systems, the resistive contribution of DC circuit breakers and inductors dominates over that of the cables, requiring a revision of standard assumptions. The analysis also identified a maximum efficiency operating point for superconducting cables, linked to the constant cooling power demand, making load flow analysis an essential tool for proper infrastructure exploitation.
Tipologia del documento
Tesi di dottorato
Autore
Guerra, Emiliano
Supervisore
Co-supervisore
Dottorato di ricerca
Ciclo
38
Coordinatore
Settore disciplinare
Settore concorsuale
Parole chiave
Superconducting DC power cables, Electro-thermal modelling, Partial inductance coefficients, DC fault transient analysis, Multi-terminal DC grids, DC power flow calculation, Smart Energy Systems
DOI
10.48676/unibo/amsdottorato/13284
Data di discussione
1 Luglio 2026
URI
Altri metadati
Tipologia del documento
Tesi di dottorato
Autore
Guerra, Emiliano
Supervisore
Co-supervisore
Dottorato di ricerca
Ciclo
38
Coordinatore
Settore disciplinare
Settore concorsuale
Parole chiave
Superconducting DC power cables, Electro-thermal modelling, Partial inductance coefficients, DC fault transient analysis, Multi-terminal DC grids, DC power flow calculation, Smart Energy Systems
DOI
10.48676/unibo/amsdottorato/13284
Data di discussione
1 Luglio 2026
URI
Statistica sui download
Gestione del documento: