Use of morselized bone allograft in revision hip arthroplasty for massive acetabular defect: a systematic review and meta-analysis

Cimatti, Pietro (2026) Use of morselized bone allograft in revision hip arthroplasty for massive acetabular defect: a systematic review and meta-analysis, [Dissertation thesis], Alma Mater Studiorum Università di Bologna. Dottorato di ricerca in Scienze chirurgiche e tecnologie innovative, 38 Ciclo.
Documenti full-text disponibili:
[thumbnail of Tesi_Cimatti_Pietro_OKPDF.pdf] Documento PDF (English) - Richiede un lettore di PDF come Xpdf o Adobe Acrobat Reader
Disponibile con Licenza: Salvo eventuali più ampie autorizzazioni dell'autore, la tesi può essere liberamente consultata e può essere effettuato il salvataggio e la stampa di una copia per fini strettamente personali di studio, di ricerca e di insegnamento, con espresso divieto di qualunque utilizzo direttamente o indirettamente commerciale. Ogni altro diritto sul materiale è riservato.
Download (4MB)

Abstract

Introduction: Several surgical options are available for the revision of large acetabular defects, but the optimal reconstruction technique remains controversial. This meta-analysis evaluated the failure rates of Paprosky type III or American Academy of Orthopaedic Surgeons (AAOS) type III–IV acetabular defects treated with morselized allograft combined with a cemented cup, cementless cup, or reinforcement device. Methods: A systematic search of PubMed/MEDLINE, EMBASE, and the Cochrane Database of Systematic Reviews was performed for studies published between January 1980 and April 2024. Eligible studies included revision total hip arthroplasty (THA) using acetabular impaction bone grafting for large acetabular defects. The primary outcome was implant failure at a mean follow-up of approximately 9 years. Results: Thirty-nine studies were included, comprising 41 treatment cohorts: morselized allograft with a cemented cup (10 studies), cementless cup (9 studies), or reinforcement device (22 studies). The overall implant failure rate was 2.1% (95% CI, 1.6–2.8%) at a mean follow-up of 9.2 years. Failure rates did not differ significantly among treatment groups: 1.6% (95% CI, 0.9–2.6%) for cemented cups, 2.1% (95% CI, 1.4–3.2%) for cementless cups, and 2.5% (95% CI, 1.7–3.7%) for reinforcement devices (p = 0.351). Aseptic loosening was the leading cause of failure (80.5%), followed by infection (13.1%) and dislocation (6.4%). Compared with cemented cups, reinforcement devices were associated with higher rates of infection (3.6% vs. 0.7%, p = 0.001) and dislocation (1.4% vs. 0.6%, p = 0.010). Conclusions: Morselized allograft provides low failure rates in the revision of large acetabular defects regardless of the implant used. However, reinforcement devices are associated with a higher risk of re-revision due to infection and dislocation.

Abstract
Tipologia del documento
Tesi di dottorato
Autore
Cimatti, Pietro
Supervisore
Co-supervisore
Dottorato di ricerca
Ciclo
38
Coordinatore
Settore disciplinare
Settore concorsuale
Parole chiave
acetabular defect; hip; morselized allograft.
Data di discussione
27 Luglio 2026
URI

Altri metadati

Statistica sui download

Gestione del documento: Visualizza la tesi

^